PRODUCTSSERVICESNEWSABOUTCONTACT

Contact Us

Need a quote or have questions? Send us a message anytime — our team is ready to assist you promptly.

Back to Water Meters
Water Meters

Ultrasonic Water Meter

CS50–200

The Ultrasonic Water Meter uses non-mechanical flow measurement for large-bore cold-water applications. The documented CS50–200 configuration supports pulse and 4–20 mA outputs, IP68 protection and a wide operating range for municipal and industrial networks.

Key Features

  • No moving measuring parts
  • DN50 to DN200 size range
  • Up to 1.6 MPa working pressure
  • IP68 protection
  • Pulse and 4–20 mA outputs
  • Range ratio of at least 1:500

TECHNICAL SPECIFICATIONS

Temperature Range

-25°C to +55°C

Pressure Rating

Up to 1.6 MPa

Diameter Range

DN50–DN200

OCTAVE-CS 50–200 Actual Technical Parameters

SizeQ4 Overload Flow (m³/h)Q3 Nominal Flow (m³/h)Q2 Transitional Flow (m³/h)Q1 Minimum Flow (m³/h)Starting Flow (m³/h)Error Q3–Q4Error Q1
DN50 (2")65400.1250.0600.025±2%±5%
DN80 (3")100630.2000.0800.025±2%±5%
DN100 (4")1501000.3200.1000.025±2%±5%
DN150 (6")3502500.6000.4000.200±2%±5%
DN200 (8")5504001.0000.8000.200±2%±5%

These values are from the actual OCTAVE-CS 50–200 technical parameter table. Confirm the selected output, pressure and configuration before ordering.

OCTAVE-CS 50–200 Evaluated Technical Parameters

SizeQ4 Overload Flow (m³/h)Q3 Nominal Flow (m³/h)Q2 Transitional Flow (m³/h)Q1 Minimum Flow (m³/h)Error Q3–Q4Error Q1
DN50 (2")50400.1250.080±2%±5%
DN80 (3")80630.2000.125±2%±5%
DN100 (4")1251000.3200.200±2%±5%
DN150 (6")3132500.8000.500±2%±5%
DN200 (8")5004001.2800.800±2%±5%

OCTAVE-CS Dimensions and Weight

SizeL Length (mm)B Width (mm)H Height (mm)h Register Height (mm)Weight (kg)
DN50200165194409
DN802252002109013
DN10025022022310315
DN15030028528214032
DN20035034033216545

Ultrasonic Meter Product Configuration

ItemDocumented Configuration
Measurement principleTransit-time ultrasonic measurement with dual-channel probes
ProtectionIP68; suitable for underwater operation
Expected battery lifeBuilt-in lithium battery; expected life up to 16 years
OutputsPositive and negative flow pulse output; dual pulse or 4–20 mA output options
DisplayTwo-row digital LCD with flow direction, instantaneous flow, cumulative volume, alarms and low-battery status
Working environment-25°C to +55°C
Maximum working pressure1.6 MPa
CommunicationInterface reserved for AMR and network monitoring

READY TO ORDER?

Contact our sales team for pricing, availability, and custom solutions tailored to your needs.